MHL Series
Heatless Regenerative D. D.
(Int. Particle/Pre/Post Filt. 300-1500scfm)
(300 scfm – 5000 scfm)
MHL Series Dryer & Filtration Packages are designed to provide very dry / higher air quality (-40 deg oF, -100 deg oF optional) for very critical compressed air applications. SIEMENS Touchscreen PLC with Pre/Post Filtration Included for Total Air Quality Management.

Conditions
Nominal
Maximum
Working Pressure
100 psi
200 psi
Inlet Temperature
100°F
120°F
Ambient Temperature
100°F
120°F
Pressure Dewpoint
- 40°F (-100 °F optional)
- 40°F (-100 °F optional)
| Inlet Temperature (°F) | 70 | 80 | 90 | 100 | 105 | 110 | 115 | 120 | |||||
| Factor F1 | 1.12 | 1.09 | 1.06 | 1.00 | 0.93 | 0.86 | 0.80 | 0.75 | |||||
| Pressure (psig) | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 130 | 140 | 150 | 175 | 200 |
| Factor F3 | 0.56 | 0.65 | 0.74 | 0.83 | 0.91 | 1 | 1.06 | 1.08 | 1.12 | 1.16 | 1.20 | 1.29 | 1.37 |